ICH110eco

Stability/Constant Climate Chamber

Internal Volume
108 L (4 cu.ft.)
Temp. Range
-10 to +60 °C
Dimensions (in)
29.25 x 48.5 x 23

Standard delivery Climate chamber

Memmert Climate Chambers Overview

Various stability/constant climate chambers, humidity chambers, and environmental test chambers are highly efficient and provide accurate controls for a homogeneous and stable environment. Learn more about the many benefits Memmert series climate chambers have to offer.

Standard Equipment

Memmert models come complete with the following list of standard equipment.

Door

Fully insulated stainless steel door with 2-point locking (compression door lock)

Inner Door

Inner glass door(s)

Internals

2 stainless steel grid(s), electropolished

Entry Port

Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by a silicone stopper, standard position at the back

Calibration Certification

Works calibration certificate standard values +10 °C and +37 °C, 60 % rh at +30 °C

Warranty

3-year warranty

Specifications

 
Model
ICH110eco
Internal volume (cuft)
4
Temp. range
From -10°C up to +60°C without humidity (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over), from +10°C up to +60°C with humidity and/or light. For the ICH110ecoL: Without humidity: 0 to +60 °C, from +10°C up to +60°C with humidity and/or light. For the ICH110C: With and without humidity: from +10°C up to +50°C.
Set Temp. Range
-10 to +60 °C/0 to +60 °C/+10 to +50 °C
Set Temp. Accuracy
0.1 °C
Sensor
2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Humidity
Humidity supply with distilled water from external tank by self-priming pump, active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity - resolution of display 0.1 %, setting accuracy 0.5 %
Light
The ICH110ecoL comes with illumination unit consisting of 3 fluorescent lights with cold white light (standard illuminant D65, 6.500K) and 2 UV-lamps in the spectral range of 320-400 nm. Daylight and UV-light can be programmed individually via controller. Cold white light +/- 6 %, for UV-light +/- 10 %
CO2
The ICH110C comes with digital electronic CO2-control with automatic zeroing (infrared measuring system) - adjustment range 0-20 % - resolution 0.1 %. CO2-supply via sterile filter. Intrinsic adjustment of altitude above sea level. CO2-supply interruption upon door opening.
Control Panel
TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays
Ventilation
Forced air circulation in working chamber adjustable from 10 to 100 % in 10 % steps. (ICH110C includes fixed value 50% when working with CO2)
Programming
AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port
Temp. Control
Mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature, over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display
AutoSAFETY
Additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature, compressor in case of undertemperature
Heating
Air jacket heating system for gentle all-around heating, no drying-up of the load caused by the cooling device due to separation of thermal jacket from interior
Cooling
Cooling compressor with climate-friendly refrigerant CO2 (R744), GWP1. (ICH110C: Energy-saving use of CFC-free cooling/heating system - refrigerant R134a)
Defrost
Highly efficient automatic defrosting system
Humidity rh
Max. 70 %, non-condensing
Interior Dims (WxHxD) in.
22 x 19 x 15.75 (d less 1.25 in. for fan)
Max. number of internals
5
Exterior dims (WxHxD) in.
29.25 x 48.5 x 23 (d +2.25in. door handle)
Weight (lbs.)
251 (ICH110C = 240)
Power
230 V, 50 Hz, approx. 1350 W (ICH110C = 115 V, 50/60 Hz, approx. 1350 W)
Warranty
3 years
Other
Available with Light (ICH110ecoL) or CO2 control (ICH110C), please inquire
Request More Info on the Memmert ICH110eco

You may also consider...

ICH260eco

The compressor-based Memmert ICH260ecoL has an internal volume of 9 cu. ft. and offers unparalleled homogeneity of temperature and humidity. Stainless steel construction, intuitive controlCOCKPIT with a 3-year warranty. The temperature range is up to +60 °C. With light (ICH260ecoL) up to +60 °C. With humidity (ICH260C) up to +50 °C.

Learn More
ICH750eco

The compressor-based Memmert ICH750eco has an internal volume of 26 cu. ft. and offers unparalleled homogeneity of temperature and humidity. Stainless steel construction, intuitive controlCOCKPIT with a 3-year warranty. The temperature range is up to +60 °C with humidity and/or light. With light (ICH750ecoL) up to +60 °C. With humidity (ICH750C) up to +50 °C.

Learn More

Resources

Below are resources to help you get familiar with Memmert Climate Chambers.

Memmert Climate Chambers Product Sheet

This product sheet provides a detailed overview of the product features, benefits, and models. (more…) read more...

File type: PDF
File size: 107.8 kb
Download now

Resource Library

Please find all articles, videos, downloads, and more in the Resource Library.

Need Help Choosing an Climate Chamber?

To help you choose the right climate chamber for your lab, we created a quick laboratory climate chamber guide to help narrow your choice.

Request Information

Fill out the form below for specific product support, questions or comments and we will get back to you as soon as possible.